PB10-8L15 Infrared Curtain Photocell

JUTAI Infrared Light Curtain Introduction

JUTAI infrared light curtain system consists of a single-chip microcomputer control board and a power supply, an infrared transmitter, and an infrared receiver. The transmitting end and the receiving end are respectively installed on both sides of the door. The single-chip microcomputer control board controls the transmitter and receiver, thus forming a light curtain between the two rows of infrared tubes. The control signal output end is connected with the controller of the door motor, If there is any obstruction between the doors, a signal will be sent to the door controller to realize the anti-pinch function(safe protection).

JUTAI Infrared Light Curtain Application

JUTAI infrared light curtain has high sensitivity, high accuracy and stable performance. It can resist magnetic interference, optical interference, waterproof and dustproof, strong seismic resistance, and has the function of self-checking fault alarm. It is widely used in industrial door control system, elevator control system, automatic door control system, passage control system, toll station vehicle detection, vehicle overrun inspection (length, width and height), passage passenger flow detection and other fields.

Description Of The Product

  • The PB10-8L15 series safety device is composed of N transmitter units and receiver units, both contained within sturdy aluminum profles. Beams of infrared rays are generated capable of detecting the presence of people and / or objects when interrupted. The communication between the transmitter unit and the receiver unit is carried out optically and, therefore, no electrical connection between the two units is necessary.

 

  • To avoid reflections and / or reception errors, a unique identifcation code is set for each infrared beam. When an object, limb or body of a person interrupts the beam of rays emitted by the transmission unit, the output is immediately opened by the receiver unit, with consequent blocking of the automation. The system is only safe when the TEST system is used, this allows you to check the correct functioning of the barrier .

 

  • Typical applications of the system include detection of people or material obstacles near access gates such as: 1.High-speed folding doors and sectional doors,  2.Sliding doors and gates.

 

Products Parameter

Number of Beams 8
Height 1045 mm
Detection Distance 15m
Working Voltage DC12-24V
Transmitter Operating Current <50mA
Receiver Operation Current <50mA
Response Time 50/100/150/200ms adjustable
Trigger Time Block a beam of light, trigger in 2 seconds, block adjacent 2 beams or more, trigger immediately
Induction Method Single beam trigger or Multi-beam trigger(can selected)
Working Temperature -20~60℃
Ambient Temperature 90%RH In Max;(No condensation)
Alarm Output Wired Output, relayOutput30VDC@2A,125VAC@1A
Output Way(Wired Model) Wired transmission,(NO/NC)
Rotation Angle 180 degrees horizontal
IP level IP65
Material Aluminum Alloy And PC Plastic

 

Products Size Photo

 

Curtain Photocell Installation

 

Operation Step

♦ Remove the Top and Bottom Cover,and connect the wires,and lead the thread end from the threaded port.

♦ Confirming the installation position , align the transmitter and receiver in parallel, and mark the hole positions.

♦ Use a percussion drill to drill holes at the location of the wall marking hole, and knock the wall plug into the fixing hole to fix it with screws.

♦ Use M3*25 screws to lock the transmitter and receiver, and connect the power supply to test. If the angle is deviated, you can rotate the aluminum tube for correction. After debugging, lock the rotating screw.

♦ Using M2*8 Screws locked top cover and bottom cover , and testing.

 

Connection Details

 

Application Layout

 

Product Operation Status And Troubleshooting

LED Indicator status( connected power)
launcher Green LED is on, Transmitter power supply is normal
Receiver Warn: Green LED is on, the red light goes out, no sound prompt
Alarm: Green LED is on, red LED is red, have a prompt

 

Phenomenon Probable cause Processing method
Connected power, The LED indicator not bright 1.The positive and negative poles of the power cord are reversed Check the positive and negative anodes power line, correct way connection the power line
2.The power voltage abnormality Measure whether the access voltage is within the range
3.The power cable is short or disconnected Check the cable routing
Alarm or false alarm all the time 1.Misalignment of eyes Rerotate and aim at the eyes
2.The installation distance is greater than the receiving distance Re-adjust the installation distance and less than the receiving distance
3.The installation position is unstable and shakes Reinstall and fix it, making sure it will not shake
4.The power voltage not stable Change the stable power supply
5.Dip settings and the photocell eyes number are correct Check the Dip setting, make sure the correct number of the photocell beam eyes
Not alarm 1.Detection object does not block the photocell beam Detection object cover the two eyes photocell beam or more
2.The single photocell beam block not enough timephotocell beam or more If use the single photocell beam, the single photocell beam block time need 2 seconds or more time
3.Reflection interference Remove reflective object or adjust the eyes direction
4.The signal line is open circuit Check the signal line

Write Us and we'll get back to you